人妻少妇精品中文字幕AV蜜桃_亚洲精品无码久久久影院相关影片_两个男人吮她的花蒂和奶水视频_超碰最新上传

Products

Home > Products Guide > DynAmp LKAT

DynAmp LKAT

DynAmp LKAT

The LKAT Plus combines high current measurement and reverse or overcurrent protection into a single rugged system. Based on innovative OLOPTM technology which is designed to accurately and reliably measure uni- and bi-directional DC and AC bus currents up to 100kA. The LKAT Plus consists of a two-piece measuring head, constructed to match the dimensions of the measured bus, electronics enclosure, mounting hardware and interconnection cables.


Application

The LKAT Plus is particularly well suited to measure power rectifiers outputs for control and protection purposes in electro-chemical processes such aluminum, chlorine, copper, manganese, titanium, zinc, electroplating, etc.

 

Key Features

? True bi-directional performance. Ideal for difficult magnetic applications.

? Setpoint relay can be used for reverse or overcurrent protection of rectifiers.

? Extremely compact with excellent environmental specifications for installation flexibility, inside or outside.

? System includes Accuracy Diagnostics.

? Optional digital display can be scaled for DC or RMS.

Specifications

Input : Full Scale Bus Current 5kA to 100 kA FS

Upon approved DynAmp Bus Analysis

Output : Output Signal Range -20mA… 20mA

10V maximum burden

Typical Output Signal Scaling BUS Signal Output

DC 0kA = 0mA or 4mA

+FS = 20mA or 20mA

DC w/ reverse or AC - FS = 4mA or -20mA

0kA = 12mA or 0mA

+ FS = 20mA or 20mA

Protection Relay Factory Scaled

DC 0 to +FS

DC w/reverse or AC -FS to +FS

Rating 250VAC / 30VDC, 3A

Timing 10mS

Measurement accuracy** ±0.75% of FS or better

Repeatability ± 0.1% of FS or better

Linearity ± 0.1% of FS or better

Temperature sensitivity** + 200 ppm / o C

Optional Digital Meter In electronics enclosure

Mains

Input : Universal power supply 85 to 264 VAC RMS,

@ 47 to 440Hz or

110 to 250 VDC

Power requirements 30VA max.

Mains impact on accuracy 120VAC: +0.001% FS

(Variation per Vrms) 240VAC: ± 0.0005% FS

Isolation ( Hi-Pot tested at 60Hz )

Head to output 6.0kVAC for 1 minute

Mains supply to output 1.0kVAC for 1 minute

Mains or Output to chassis 2.0kVAC for 1 minute

Environmental

Operation : Head -20o to 80oC

Electronics :-10o to 50oC

Storage : System -20o to 65oC

Physical

Measuring head weight 2…8 lbs/1…4 kg typical

Electronics unit weight 10 lbs / 5.5 kg estimate

Cables Head connection 2 @ 33 Ft / 10 m std.

Signal output 1 @ 100Ft / 30 m std.

Mains input 1 @ 33 Ft / 10 m std.

Enclosure Head/Electronics IP65


人妻少妇精品中文字幕AV蜜桃_亚洲精品无码久久久影院相关影片_两个男人吮她的花蒂和奶水视频_超碰最新上传